CAUTION
When putting generator (1) in chain vise, do not clamp
vise over nameplates and raised surfaces. Generator
can come loose and damage equipment.
1. Put generator (1) on mounting bracket (2) and tighten chain vise (3).
2. Loosen four nuts (4) and aline generator pulley (5) with test stand pulley (6).
Tighten four nuts.
3. Loosen four nuts (7) behind generator mounting bracket (2). Lift mounting
bracket and place belts (8) on test stand pulley (6) and generator pulley (5).
4. Take up slack on belts (8) and tighten four nuts (7).
I
END OF TASK
TA 118944
2-217
|