FRAME 2
CAUTION
Do not use a battery or test lamp to make a continuity
test. Reverse battery connection will burn out diodes
instantly.
Check stator (1) for continuity using multimeter. Touch test probe of
1.
multimeter to each pair of stator leads (2). If there is not continuity between
all three stator leads, generator is not repairable.
2.
Check that stator shroud (3) is not cracked or broken. If shroud is damaged,
generator is not repairable.
NOTE
On ohmmeters that use one 1 l/2-volt dry cell, low
resistance readings will be approximately 20 to 30
ohms. On ohmmeters that use a 3-volt dry cell,
low resistance readings will be approximately 10 to
15 ohms.
Using multimeter, check three positive rectifiers (4) by touching positive
3.
test probe of multimeter to base of rectifier and negative test probe to top
of rectifier. Multimeter must show low resistance. If multimeter does not
show low resistance, get a new rectifier.
4.
Using multimeter, check three negative rectifiers (5) by touching positive
test probe of multimeter to base of rectifier and negative test probe to the
top of rectifier. Multimeter must show low resistance. If multimeter
does not show low resistance, get a new rectifier.
GO
TO FRAME 3