NOTE
If rotor (1) is not within limits given in table 2-10,
generator is nonrepairable.
Measure
outside diameter of shaft (2) at end housing.
1.
Measure
outside diameter of sliprings (3).
2.
Measure
outside diameter of drive end bearing seat (4).
3.
Measure
outside diameter of drive end of shaft (5),
4.
NOTE
If end housing (6) is not within limits given in table
2-10, generator is nonrepairable.
Measure
inside diameter of end housing bearing bore ( 7).
5.
NOTE
If bearing
(8) is not within limits given in table 2-10,
get a new
bearing.
6.  Measure bearing (8)
inside diameter (9).
7.  Measure bearing (8)
outside diameter ( 10).
GO TO FRAME 2
NOTE: CHECK ONLY THOSE PARTS WHICH
10
ARE CALLED OUT IN THIS FRAME.
o
PARTS WITHOUT CALLOUTS ARE
SHOWN ONLY FOR REFERENCE
PURPOSES OR ARE CHECKED IN
ANOTHER FRAME.
TA 103688