TM 9-2920-225-34
Check that housing (1) is not cracked or damaged. If housing is damaged,
1.
generator is nonrepairable.
Measure inside diameter of bearing bore (2). Inside diameter of bearing bore
2.
must be 1.3095 to 1.3105 inches. If bearing bore is not within given limits,
--
generator is nonrepairable.
NOTE
If bearing (3) is not within given limits, get a new
bearing.
Measure inside diameter (4) of bearing (3). Inside diameter must be 1.0005
3.
go gage to 1.0015 inches no-go gage when held in 1.3120 ring gage.
Measure bearing (3) outside diameter (5). Outside diameter must be 1.3120
4.
inches nominal when pushed into 1.3120 inches ring gage.
Check that bearing (3) is not damaged. Refer to TM 9-214.
5.
GO
TO FRAME 2
TA 103605
2-105
|