d.  Cleaning.  There are no special cleaning procedures needed. Refer to
cleaning procedures given in para 1-3.
e. Inspection and Repair.
(1) Inspection.
NOTE
Readings for rotor (1) and drive end bell (2) must be
within limits given in table 2-4. If readings are not
within given limits, generator is nonrepairable.
Measure outside diameter of sliprings (3).
1.
Measure outside diameter of slipring end of shaft (4).
2.
Measure outside diameter of drive end of shaft bearing seat (5).
3.
4.
Measure outside diameter of drive end of shaft (6).
5.
Measure inside diameter of drive end bell bearing bore (7).
NOTE
If bearing (8) is not within limits given in table 2-4,
get a new bearing.
Measure outside diameter (9) of drive end bearing (8).
6.
Measure inside diameter (10) of drive end bearing (8).
7.
GO TO FRAME 2