TM 9-2920-225-34
I
1.
Put lead from connector socket (1) on negative rectifier stud (2) with nut
and lockwasher ( 3).
2.
Solder capacitor lead (4) to connector socket ( 1).
3.
Solder leads from brush holder (5) to connector socket (1).
4.
Put connector socket (1) in place with two screws (6).
5.
Put brush holders (5) in place with two screws ( 7), lockwashers (8), and
guard washers (9).
IF WORKING ON EARLY MODEL GENERATOR, GO TO FRAME 6.
IF WORKING ON LATE MODEL GENERATOR, GO TO FRAME 7
TA103574