TM 9-2920-225-34
FRAME 2
I
NOTE
Early model generator has two insulator mounts (1).
Positive rectifier (3) has an epoxy coating for insulation.
Put insulator mount (1) and two rectifiers (2 and 3) into housing (4) as
1.
marked.
Put two screws (5) and nut (6) into negative rectifier (2).
2.
Put two screws (5) and guard washers (7) and three insulator washers (8)
3.
into positive rectifier (3).
G O TO FRAME 3
TA103572
2-71
|