TM 9-2920-225-34
FRAME 3
Take out two screws ( 1), lockwashers ( 2), and guard washers (3) from brush
1.
holder (4).
Take out two screws (5) from connector socket (6).
2.
Unsolder leads from brush holder (4) at connector socket (6) and take out
3.
brush holder.
Unsolder capacitor lead (7) at connector socket (6).
4.
Take off nut and lockwasher (8).
5.
Take connector socket (6) out of housing (9).
6.
GO TO FRAME 4
NOTE
PARTS WITHOUT CALLOUTS ARE SHOWN
ONLY FOR REFERENCE PURPOSES.
TA103563