Click here to make tpub.com your Home Page

Page Title: FRAME 2
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2920-225-34
FRAME 2
1.
Check that drive end bell (1) has no cracks, warping or other damage. If
drive end bell is damaged, generator is nonrepairable.
Check drive end bell bearing (2). Refer to TM 9-214. Get a new bearing
2.
if it is damaged or worn.
Check that screws (3) are not bent or broken and that they have no damaged
3.
threads.  If screws are damaged, get new ones.
4.
Check that rotor (4) has no grounds by using a multimeter and touching one
test probe to rotor shaft (5) and the other to one slipring (6). Ohmmeter
readings must be more than 10,000 ohms.  If reading is not more than 10,000
ohms, generator is nonrepairable.
Do step 4 again for other slipring (6).
5.
Check resistance of sliprings (6) by using a multimeter and touching ohm-
6.
meter probes on each slipring (6). Resistance must be between 7.0 and
7.8 ohms.  If not within given limits, generator is nonrepairable.
GO TO FRAME 3
TA103553
2-53

Privacy Statement - Press Release - Copyright Information. - Contact Us