TM 9-2920-225-34
1.
Check that preformed packings (1 and 2) and seal (3) are not damaged or
worn. If packings or seal are damaged, generator is nonrepairable.
2.
Check that drive end housing (4), bearing retainer (5), and sleeve spacer
(6) are not cracked, warped or damaged. If parts are damaged, generator
is nonrepairable.
Measure inside diameter of drive housing bearing bore (7). Bore must be
3.
2.0471 to 2.0477 inches. If bore is not within given limits, generator is
non-repairable.
GO TO FRAME 4