Click here to make tpub.com your Home Page

Page Title: FRAME 4
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2920-225-34
FRAME 4
1.
Check rectifier (1) using multimeter as follows.
NOTE
On ohmmeters that use one 1 1/2-volt dry cell, low resist-
ance readings will be approximately 20 to 30 ohms. On
ohmmeters that use a 3volt dry cell, low resistance
readings will be approximately 10 to 15 ohms.
Touch positive test probe of multimeter to screw hole (2). Multimeter must
2.
show low resistance when negative test probe is touched to rectifier
terminals (3, 4, and 5).  Get a new rectifier (1) if it does not show correct
reading.
Touch negative test probe of multimeter to screw hole (2). Multimeter must
3.
show infinite resistance when positive test probe is touched to rectifier
terminals (3, 4, and 5). Get a new rectifier (1) if it does not show correct
reading.
END OF TASK
TA103511
2-13

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business