1-1.
SCOPE .
This technical manual gives instructions for direct support and general
support maintenance of Leece-Neville generator models 3002AC, 3002AD , 3002AE ,
5504AA, 5004AB, 2184AC and 5300GP and Prestolite generator model AMA-5102UT.
This manual gives procedures for disassembly, cleaning, inspection, repair,
assembly, testing and adjustment as directed by the maintenance allocation chart.
Figure 1-1 shows the different models of generators that you will be working on.
b.
Appendix A gives a list of current and applicable references covered in
this manual.
Refer to TM 9-2920-225-34P for a listing of parts and special tools for the
c.
models of generators covered in this manual.
a.
Chapter 2 gives instructions for disassembly of the generator. However,
the generator should not be taken apart beyond the point needed to repair or re-
place parts found damaged during inspection.  You must use your judgment in
following the disassembly procedures so you do only those operations that are
necessary.
b.
Troubleshooting a fault within a generator is done as part of the repair
procedures; therefore, it should be noted that a component which is damaged or
not working will be found as part of inspection, repair, and test procedures given
in this manual.  Corrective action will be repair or replacement as authorized at
this level of maintenance.
.
1-3.  CLEANING .
WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame. Keep a fire extinguisher
nearby when solvent is used. Use only in well-
ventilated places. Failure to do this may result
in injury to personnel and damage to equipment.
Eye shields must be worn when using compressed
air. Eye injury can occur if eye shields are not
used.
a. Before taking generator apart, clean exterior with dry cleaning solvent.
Dry thoroughly with compressed air.
b. Except where special cleaning procedures are given for a component or part,
clean all components and parts with dry cleaning solvent. Dry thoroughly with com-
pressed air.