Click here to make tpub.com your Home Page

Page Title: FRAME 2
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2815-210-34-2-2
FRAME 2
O p e n adjustable valve (1) and start fuel pump.
1.
K e e p valve (1) open until system is purged of air.
2.
Close valve (1).
3.
T u r n rheostat (2) until voltmeter (3) reads 24 volts.
4.
P r e s s u r e gage (4) should read 90 to 100 psi.
5.
T o set pressure, if necessary, loosen check valve locknut (5)' with wrench.
6.
T u r n relief valve adjusting screw (6) with screwdriver until pressure gage
reads 90 to 100 psi.  H o l d relief valve adjusting screw with screwdriver and
t i g h t e n check valve locknut with wrench.
END OF TASK
4-534

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business