S e t depth micrometer (1) to 1.705 inches.
1.
T a k e off adjusting screw lockplates or loosen locknuts (2).
2.
U s i n g spanner wrench socket (3), turn release lever adjusting nut (4) until
3.
m i c r o m e t e r (1) touches release lever (5) and micrometer anvil (6) touches
clutch spacer plate (7).
D o step 3 again for other three release levers (5).
4.
W h e n distance in steps 3 and 4 is 1.674 to 1.736 inches, heights of four release
5.
l e v e r s (5) must be within 0.015 inch of each other.
Do steps 3 and 4 again if needed.
6.
7.
P u t on adjusting screw lockplates or tighten locknuts (2).