TM
9-2815-210-34-2-2
FRAME 2
1.
P u t nozzle and holder assembly (1) in soft-jawed vise. Tighten locknut (2)
t o 40 to 45 pound-feet. T a k e nozzle and holder assembly out of vise.
D o nozzle opening pressure test, para 4-40a (1). If adjustment is not right,
2.
do frame 1 and step 1 of this frame. If adjustment is still not right, disassemble
clean and inspect, and repair nozzle. Refer to para 4-40b, c, and d.
3.
P u t nozzle and holder assembly (1) in soft-jawed vise. Hold locknut (2) and
t i g h t e n cap (3) to 40 to 45 pound-feet. T a k e nozzle and holder assembly out
of vise.
END OF TASK
4-397
|