TM
9-2815-210-34-2-2
FRAME 2
1.
C h e c k that oil cooler (1) has no cracks. If oil cooler is damaged, get a new
one.
WARNING
D r y cleaning solvent is flammable. Do not use near
an open flame. K e e p a fire extinguisher nearby when
s o l v e n t is used. U s e only in well-ventilated places.
Failure to do this may result in injury to personnel
a n d damage to equipment.
C h e c k that gasket surface (2) of oil cooler (1) and oil cooler cover (3) have
2.
n o nicks, burrs or scratches. Take out minor nicks, burrs or scratches
w i t h a fine mill file or crocus cloth dipped in dry cleaning solvent. If more
r e p a i r is needed, get a new part.
END OF TASK