FRAME
2
WARNING
D r y cleaning solvent is flammable. Do not use near
an open flame.  K e e p a fire extinguisher nearby when
s o l v e n t is used.  U s e only in well-ventilated places.
F a i l u r e to do this may result in injury to personnel
a n d damage to equipment.
1.
C h e c k that pump adapter (1) is not cracked or bent and has no nicks, burrs
o r scratches on gasket surfaces.  F i x minor nicks, burrs or scratches with
a fine mill file or crocus cloth dipped in dry cleaning solvent. If more
r e p a i r is needed, get a new part.
2.
C h e c k that drive gear (2) has no cracks, nicks, burrs, scratches or worn or
c h i p p e d g e a r t e e t h .  T a k e out minor nicks, burrs or scratches with a fine
m i l l file or crocus cloth dipped in dry cleaning solvent. If more repair is
n e e d e d , get a new part.
GO TO FRAME 3
NOTE :
CHECK ONLY THOSE PARTS WHICH
ARE CALLED OUT IN THIS FRAME.
PARTS WITHOUT CAL LOUTS ARE
SHOWN ONLY FOR REFERENCE
PURPOSES OR ARE CHECKED IN
ANOTHER FRAME.
TA 121140
4-373