TM
9-2815-210-34-2-2
FRAME 2
WARNING
D r y cleaning solvent is flammable. Do not use near
an open flame. K e e p a fire extinguisher nearby when
s o l v e n t is used. Use only in w en-ventilated places.
F a i l u r e to do this may result in injury to personnel
a n d damage to equipment.
C h e c k that pump adapter (1) and manifold assembly
(2) are not cracked,
1.
b e n t , dented and have no nicks, burrs or scratches
on gasket surfaces.
T a k e out minor nicks, burrs or scratches with a fine
mill file or crocus
c o t h dipped in dry cleaning solvent. I f more repair
is needed, get a new
part.
2.
C h e c k that drive gear (3) has no cracks, nicks, burrs, scratches or worn
o r chipped gear teeth. T a k e out minor nicks, burrs or scratches with a fine
m i l l file or crocus cloth dipped in dry cleaning solvent. If more repair
i s needed, get a new part.
GO TO FRAME 3
NOTE :
CHECK ONLY THOSE PARTS WHICH
ARE CALLED OUT IN THIS FRAME.
PARTS WITHOUT CALLOUTS ARE
SHOWN ONLY FOR REFERENCE
PURPOSES OR ARE CHECKED IN
ANOTHER FRAME.
TA121130
4-363
|