(2) Cleaning.
FRAME
1
WARNING
D r y cleaning solvent is flammable. Do not use near
a n open flame. K e e p a fire extinguisher nearby when
s o l v e n t is used. U s e only in well-ventilated places.
Failure to do this may result in injury to personnel
a n d damage to equipment.
1.
C l e a n flywheel housing (1) with dry cleaning solvent. Dry with clean cloth.
2.
C l e a n threaded fittings with dry cleaning solvent. Let fittings air dry.
END OF TASK