TM 9-2520-246-34-1
2-26. CLEANING . This paragraph gives general instructions for cleaning the
transmission power takeoff parts.
a. Clean all bearing cones and cups. Refer to inspection, care, and maintenance
of antifriction bearings, TM 9-214.
WARNING
Dry cleaning solvent is flammable. DO not use
near an open flame. Keep a fire extinguisher
nearby when solvent is used. Use only in well-
ventilated places. Failure to do this may result
in injury to personnel and damage to equipment.
Do not use more than 30 psi of air pressure for
drying parts. Eye shields must be worn when
using compressed air. Eye injury can occur if
eye shields are not used.
CAUTION
When scraping gasket material from surface of
parts, be careful not to scratch or gouge the
metal surface.
b. Clean all other parts with solvent. Scrape all gasket material from surface of
parts. Rinse parts in clean solvent and dry with compressed air.
2-27. GENERAL INSPECTION. This paragraph gives instructions to check for
damage on the transmission power takeoff housings, gear shafts, and gears.
CAUTION
It is easy to damage the equipment if you don't
know what you're doing. Do not try to do this
task unless you are experienced at it, or you
have an experienced person with you.
NOTE
Small chips, burrs or scratches on gears and
gear shafts can be repaired. Cracks in housing
castings that do not go into screw holes or
openings can be repaired. If parts are damaged
in any other way, throw away parts and get new
ones.
2-309
|