TM 9-2520-246-34-1
FRAME 2
Set up dial indicator (1) as shown.
1.
2.
Push rear output shaft (2) toward rear of transfer case (3).
3.
Set dial indicator (1) to zero.
Pull rear output shaft (2) toward dial indicator (1) and note dial indicator reading.
4.
Take off dial indicator (1).
5.
IF READING IN STEP 4 IS MORE THAN 0.005-INCH, GO TO FRAME 3.
IF READING IN STEP 4 IS 0.003 TO 0.00-INCH, END OF TASK
2-269
|