TM 9-2320-366-20-3
7-73. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 24 VDC CABLE
REPLACEMENT (CONT)
b. Installation.
(1) Install three clamps (1) on 100 amp alternator to reverse
polarity relay 24 vdc cable (2).
NOTE
Install plastic cable ties as required.
(2) Position 100 amp alternator to reverse polarity relay 24
vdc cable (2) on engine (3) with three clamps (1),
washers (4), and screws (5).
(3) Tighten three screws (5) to 22-27 lb-ft (31-37 Nm).
(4) Install 100 amp alternator to reverse polarity relay 24 vdc
cable (2) in dust boot (6).
CAUTION
Insulation washer must be installed with flat
side up. Failure to comply may result in
damage to equipment.
(5) Position terminal lugs TL6 (7) and TL2 (8) on alternator
(9) with insulation washer (10), washer (11) and
self-locking nut (12).
(6) Tighten self-locking nut (12) to 40 lb-in. (5 Nm).
(7) Position dust boot (6) on terminal lugs TL2 (8) and TL6
(7).
7-342
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |