7-34. M1089 WRECKER CONTROL PANEL TOGGLE SWITCH REPLACEMENT (CONT)
(6) Disconnect conductor splice (19) from two wires (20).
(7) Remove conductor splice (21) and EMERGENCY
SHUTDOWN toggle switch (18) from wire (22).
(8) Remove  conductor  splices  (19  and  21)  from
EMERGENCY SHUTDOWN toggle switch (18). Discard
conductor splices.
b. Installation.
NOTE
Steps (1 through 6) apply to the remaining
five toggle switches.  Two toggle switches
have  three  electrical  connections,  the
remaining three have only two electrical
connections.  EMERGENCY SHUTDOWN
toggle switch shown.
(1) Position insulation sleeving (1) over two wires (2).
(2) Position insulation sleeving (1) over wire (3).
(3) Install conductor splices (4 and 5) on EMERGENCY
SHUTDOWN toggle switch (6).
(4) Install conductor splice (5) on wire (3).
(5) Install conductor splice (4) on two wires (2).
7-204