TM 9-2320-366-20-3
7-27. M1084/M1086 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT)
(29) Install right proximity sensor cable (60) in junction box
(1) with conduit nut (61).
(30) Connect quick disconnect terminal (62) to ground strip
(13) position 17.
(31) Install two terminal lugs (63) on terminal block (21)
position 6 and 11 with two screws (64).
(32) Close cover (9) on junction box (1).
(33) Tighten four screws (8) on junction box (1).
e. Follow-On Maintenance.
(1) Connect batteries (para 7-57).
(2) Operate crane and check all crane functions (TM 9-
2320-366-10-1).
End of Task.