TM 9-2320-366-20-3
7-24. FAN AND DIFFERENTIAL LOCK SOLENOIDS REPLACEMENT (CONT)
(6) Remove two screws (12) and bracket (10) from
solenoids (13).
(7) Remove 90-degree fitting (6) from solenoids (13).
(8) Remove two fittings (8) from solenoids (13).
(9) Remove plug (14) from solenoids (13).
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply antiseize compound to threads of plug (1), two
fittings (2), and 90-degree fitting (3).
(2) Install plug (1) in solenoids (4).
(3) Install two fittings (2) in solenoids (4).
(4) Install 90-degree fitting (3) in solenoids (4).
(5) Install bracket (5) on solenoids (4) with two screws (6).
7-132
|