TM 9-2320-366-20-3
d. Installation.
(1) Install decal (1) on auxiliary panel housing (2).
(2) Route auxiliary panel cable assembly (3) in
auxiliary panel housing (2).
(3) Position auxiliary panel housing (2) on heater
assembly (4) with eight screws (5).
(4) Tighten eight screws (5) to 35-44 lb-in. (4-5 Nm).
NOTE
Perform steps (4.1) and (4.2) on models
M1090 and M1094.
(4.1) Route connector J925 (5.1) auxiliary panel jumper
cable assembly (3) in auxiliary panel housing (2).
(4.2) Connect connector P925 (5.3) to connector J925
(5.1)
(5) Position tachometer (6) in auxiliary panel (7) with
retaining ring (8) and two self-locking nuts (9).
(6) Tighten two self-locking nuts (9) to 9 lb-in. (1 Nm).
(7) Install two protective caps (10) on tachometer (6).
(8) Connect connector P901 (11) to tachometer
connector (12).
(9) Connect connector clamp (13) on tachometer
connector (12).
7-36
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |