(13) Deleted.
(14) Deleted.
(15) Deleted.
(16) Deleted.
(17) Position preformed packing (25) and fuel level sending
unit (26) in fuel tank (23) with five screws (27).
(17.1) Tighten five screws (27) to 20-24 lb-in. (2-3 Nm).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.  If
adhesive, solvent, or sealing compound
gets  on  skin  or  clothing,  wash
immediately with soap and water. Failure
to  comply  may  result  in  injury  to
personnel.
(18) Apply sealing compound primer to threads of 90-degree
return fitting (28), 90-degree pickup tube fitting (29), and
relief valve (30).
(19) Apply sealing compound to threads of 90-degree return
fitting (28), 90-degree pickup tube fitting (29), and relief
valve (30).
(20) Install 90-degree return fitting (28) in fuel tank (23).
(21) Install 90-degree pickup tube fitting (29) in fuel tank (23).
(22) Install relief valve (30) in fuel tank (23).