(19) Remove screw (31) and washer (32) from resilient mount
(33).
(20) Remove three self-locking nuts (34) and screws (35)
from mounting brackets (36). Discard self-locking nuts.
(21) Remove intake air cleaner assembly (37) from three
mounting brackets (36) and resilient mount (33).
(22) Remove screw (38), washer (39), and resilient mount
(33) from mounting bracket (36).
d. M1093/M1094 Intake Air Cleaner Assembly Removal.
(1) Remove dust cap (1) from connector J106 (2).
(2) Remove nut (3), dust cap lanyard (4), and connector
J106 (2) from chemical detector mounting bracket (5).
(3) Remove four screws (6) and washers (7) from chemical
detector mounting bracket (5).
(4) Disconnect air filter restriction gauge hose (8) from air
flow sensor (9).