|
|
TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
NOTE
Tag air hose and connection point prior to
disconnecting.
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Disconnect air hose from actuator listed in
Table 2-66. Wrecker Function Solenoid
Valves and Actuators.
(2) Install test adapter on solenoid valve.
(3) Install STE/ICE-R 0-1000 psi transducer on
test adapter.
(4) Start engine (TM 9-2320-366-10-1).
(5) Position WRECKER REMOTE CONTROL
switch listed in Table 2-67. Wrecker
Function Actuator.
(6) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(7) If 75 to 120 psi (517 to 827 kPa) is not
present, replace air hose (para 23-5).
(8) If 75 to 120 psi (517 to 827 kPa) is
present, notify DS Maintenance.
(9) Shut down engine (TM 9-2320-366-10-1).
(10) Drain air tanks (TM 9-2320-366-10-1).
(11) Remove STE/ICE-R and test adapter from
solenoid valve.
(12) Install air hose on actuator.
(13) Install front middle and lower panel covers
(para 17-20).
(14) Install top control panel cover
(para 17-20).
Change 1
2-2433/(2-2434 Blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |