|
|
TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
NOTE
Tag air hose and connection point prior to
disconnecting
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Remove wrecker control panel top cover
(para 14-4).
(2) Disconnect air hose from input fitting of
30K winch manifold assembly.
(3) Connect air hose to M1089 30K winch
pneumatic test adapter.
(4) Install STE/ICE-R 0-1000 PSI transducer in
M1089 30K winch pneumatic test adapter.
(5) Start engine (TM9-2320-366-10-1) and
allow vehicle to build air pressure.
(6) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(7) If 75-120 PSI (518-827 kPa) is not present,
replace air hose (para 23-5).
(8) Shut down engine (TM 902320-366-10-1).
(9) Drain air tanks (TM9-2320-366-10-1).
(10) Remove STE/ICE-R 0-1000 PSI transducer
from M1089 30K winch pneumatic test
adapter.
(11) Disconnect air hose from M1089 30K
winch pneumatic test adapter.
Change 1
2-2428.5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |