(1) Open LH and RH catwalks.
(2) Disconnect air hose from pneumatic
manifold solenoid L19 port 1.
(3) Remove tube nipple from M1089 30K
winch pneumatic test adapter.
(4) Connect M1089 30K winch pneumatic test
adapter on pneumatic manifold solenoid
L19 port 1.
(5) Install STE/ICE-R 0-1000 PSI transducer on
M1089 30K winch pneumatic test adapter.
(6) Start engine (TM 9-2320-366-10-1) and
allow vehicle to build air pressure.
(7) Position MAIN WINCH LH FREESPOOL
switch to ON.
(8) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(9) If 75-120 PSI (518-827 kPa) is not present,
repair 30K winch pneumatic solenoid or
replace solenoid L19 (para 17-29).
(10) Shutdown engine (TM 9-2320-366-10-1).
(11) Drain air tanks (TM 9-2320-366-10-1).
(12) Position MAIN WINCH LH FREESPOOL
switch to OFF.
(13) Disconnect M1089 30K winch pneumatic
test adapter from pneumatic solenoid L19
port 1.
(14) Connect air hose to pneumatic solenoid
L19 port 1.
(15) Close LH and RH catwalks.