TM 9-2320-366-20-3
WARNING
Drop hydraulic pressure to zero before
disconnecting any hydraulic hoses. Failure
to comply may result in injury to
personnel.
Hydraulic fluid (MIL-H-5606) is TOXIC.
Wear protective goggles and gloves; use
only in well ventilated area; avoid contact
with skin, eyes, and clothes. Skin and
clothing that come into contact with
hydraulic fluid should be washed
immediately. Saturated clothing should be
removed immediately. Failure to comply
may result in injury to personnel.
PRESSURE TEST
(1) Position drain pan under spare tire retainer
cylinder.
(2) Disconnect SPARE EXT pressure hose
from spare tire retainer cylinder port.
(3) Connect STE/ICE-R to SPARE EXT pressure
hose.
(4) Start engine and charge air tanks
(TM 9-2320-366-10-1).
(5) Position SPARE TIRE knob to RAISE.
(6) Position FUNCTION SELECT knob
to SPARE TIRE.
(7) Push and hold PUMP plunger button
and perform STE-ICE-R Test #51
(TM 9-4910-571-12&P).
(8) If pressure is not 2,500-4,000 psi (17,237-
27,580 kPa), repair hydraulic manifold
SPARE TIRE valve (para 19-4).
(9) If pressure is 2,500-4,000 psi (17,237-
27,580 kPa), replace spare tire retainer
cylinder (para 14-9 or 14-10).
(10) Drain air tanks (TM 9-2320-366-10-1).
(11) Disconnect STE/ICE-R from pressure
hose.
(12) Connect pressure hose to spare tire retainer
cylinder port.
Change 1