TM 9-2320-366-20-3
TM
WARNING
Drop hydraulic pressure to zero
before disconnecting any
hydraulic line. Failure to comply
may result in injury to
personnel.
Wear approved eye protection when
performing pressure checks. Failure
to comply may result in oil getting
into eyes. If oil contacts eyes, seek
medical attention immediately.
Fuel and oil are slippery and can
cause falls. Wipe up spilled fuel
or oil with rags. Failure to comply
may result in injury to personnel.
HAND PUMP TEST
(1)
Disconnect hand pump delivery line from elbow
at hand pump.
(2)
Place drain pan under port at pump to catch
hydraulic fluid.
(3)
Pump hand pump (TM 9-2320-366-10-1).
(4)
Check if hydraulic fluid pumps out of port with
each stroke.
(5)
If little or no fluid pumps out, replace hand pump
(para 17-10).
(6)
Connect delivery line to elbow at hand pump.
(7)
Remove drain pan.
2-2411/(2-2412 Blank)
2-2411/(2-2412
|