TM 9-2320-366-20-3
TM
CONTINUITY TEST
(1)
Disconnect winch remote control cable from
winch remote control connector.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
right middle post of out solenoid.
(4)
Connect negative (-) probe of multimeter to
winch remote control connector pin B and note
reading on multimeter.
(5)
If continuity is not present, replace power
harness (para 20-60).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
winch remote control cable socket A.
(3)
Connect negative (-) probe of multimeter to
winch remote control cable socket B.
(4)
Position winch remote control switch to
out and note reading on multimeter.
(5)
If continuity is not present, replace winch
remote control cable.
(6)
If continuity is present, replace LMHC winch
assembly (para 20-60).
(7)
Connect winch remote control cable to winch
remote control connector.
(8)
Install cover on base plate with 18 screws.
2-2407/(2-2408 Blank)
2-2407/(2-2408
|