TM 9-2320-366-20-3
TM
CONTINUITY TEST
(1)
Disconnect winch remote control cable from
winch remote control connector.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
top middle post of in solenoid.
(4)
Connect negative (-) probe of multimeter to
winch remote control connector pin A and note
reading on multimeter.
(5)
If continuity is not present, replace power
harness (para 20-60).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
winch remote control cable connector socket
A.
(3)
Connect negative (-) probe of multimeter to
winch remote control cable connector socket
B.
(4)
Position winch remote control switch to OUT
and note reading on multimeter.
(5)
Connect positive (+) probe of multimeter to
winch remote control cable connector socket
A.
(6)
Connect negative (-) probe of multimeter to
winch remote control cable connector socket
C.
(7)
Position winch remote control switch to in and
note reading on multimeter.
(8)
If continuity is not present, replace winch
remote control cable.
(9)
If continuity is present, replace LMHC winch
assembly (para 20-60).
(10)
Connect LMHC control power cable to LMHC
winch assembly power connector.
(11)
Connect winch remote control cable to
winch remote control connector.
(12)
Install cover on base plate with 18 screws.
2-2399
|