CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
one end of LMHC control box circuit breaker.
(3)
Connect negative (-) probe of multimeter to
other end of LMHC control box circuit breaker.
(4)
Position LMHC control box circuit breaker to
ON and note reading on multimeter.
(5)
If continuity is not present, replace LMHC
control box circuit breaker (para 20-67).
(6)
Position LMHC control box circuit breaker to
OFF.
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
LMHC control box circuit breaker outlet post.
(3)
Connect negative (-) probe of multimeter to
LMHC control box connector pin A and note
reading on multimeter.
(4)
If continuity is not present, replace wire 592
(para 20-70).
(5)
Close cover on LMHC control box.
(6)
Connect LMHC control box power cable to
LMHC control box connector.