TM 9-2320-366-20-3
TM
x19. LIGHT MATERIAL HANDLING CRANE (LMHC) DOES NOT OPERATE (CONT)
x19.
KNOWN INFO
TEST OPTIONS
4.
Engine starts.
Continuity Test or
Is continuity present
NATO power cable OK.
STE/ICE-R #91
from NATO plug positive
REASON FOR QUESTION
NATO plug OK.
POSSIBLE PROBLEMS
If continuity is not present,
(+) terminal to LMHC
Faulty wire 170.
wire 170 is faulty.
control box circuit
Faulty circuit breaker.
breaker supply post?
Faulty wire 150.
Faulty wire 592.
NO
Faulty power cable.
Faulty power harness.
Faulty out solenoid.
Replace wire 170
Faulty in solenoid.
(para 20-70).
YES
Faulty LMHC winch
assembly.
Faulty winch cable.
KNOWN INFO
TEST OPTIONS
5.
Engine starts.
Continuity Test or
Is continuity present
NATO power cable OK.
STE/ICE-R #91
REASON FOR QUESTION
from NATO plug negative
NATO plug OK.
If continuity is not present,
(-) terminal to LMHC
Wire 170 OK.
POSSIBLE PROBLEMS
wire 150 is faulty.
control box connector
Faulty wire 150.
pin B?
Faulty circuit breaker.
Faulty wire 592.
NO
Faulty power cable.
Faulty power harness.
Faulty out solenoid.
Replace wire 150
Faulty in solenoid.
YES
(para 20-70).
Faulty LMHC winch
assembly.
Faulty winch cable.
2-2386
|