TM 9-2320-366-20-3
TM
CONTINUITY TEST
(1)
Lift instrument panel assembly outward to
gain access (para 7-15).
(2)
Disconnect connector P31 from connector
J31.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter
to connector P39-2.
(5)
Connect negative (-) probe of multimeter
to connector P31-17 and note reading
on multimeter.
(6)
If continuity is not present, repair wire 32
assembly (para 7-80).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P39-1.
(3)
Connect negative (-) probe of multimeter to
connector P31-9 and note reading on
multimeter.
(4)
If continuity is not present, repair wire 3028
assembly (para 7-80).
(5)
Connect connector P39 to connector J39.
(6)
Connect connector clamp to connector J39.
2-2379
|