CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Disconnect connector clamp from connector
J39.
(3)
Disconnect connector J39 from connector
P39.
(4)
Connect positive (+) probe of multimeter
to connector P921-A.
(5)
Connect negative (-) probe of multimeter
to connector J39-2 and note reading on
multimeter.
(6)
If continuity is not present, repair wire 32
(para 2-45) or replace troop transport
alarm cable assembly (para 20-69).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to connector P921-C.
(3)
Connect negative (-) probe of multimeter
to connector J39-1 and note reading on
multimeter.
(4)
If continuity is not present, repair wire
3028 (para 2-45) or replace troop transport
alarm cable assembly (para 20-69).
(5)
Connect connector P921 to connector J921.
2-2377
|