TM 9-2320-366-20-3
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to terminal lug TL164.
(3)
Connect negative (-) probe of multimeter
to connector J921-A and note reading on
multimeter.
(4)
If continuity is not present, repair wire 32
(para 2-45) or replace troop transport
alarm switch connector (para 20-70).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to terminal lug TL165.
(3)
Connect negative (-) probe of multimeter
to connector J921-C and note reading on
multimeter.
(4)
If continuity is not present, repair wire
3028 (para 2-45) or replace troop transport
alarm switch connector (para 20-70).