x6. NO POWER TO SINGLE CHANNEL GROUND & AIR BORNE RADIO (SINCGARS)/FORCE XXI
BATTLE COMMAND BRIGADE OR BELOW (FBCB) (CONT)
TEST OPTIONS
TEST OPTIONS
2.
Continuity Test or
Circuit breaker CB8 is not
STE/ICE-R Test #91
tripped.
Is continuity present through
REASON FOR QUESTION
circuit breaker CB8?
POSSIBLE PROBLEMS
If continuity is not present,
circuit breaker CB8 is faulty.
Faulty circuit breaker CB8.
If continuity is present,
Faulty digitization rack power
perform Special Purpose Kits
supply.
Troubleshooting task x1. No
Power to Digitization Rack.
NO
Replace circuit breaker CB8
YES
(para 20-80).
Perform Special Purpose Kit
Troubleshooting task x1. No Power
to Digitization Rack.
2-2302