TM 9-2320-366-20-3
PRESSURE TEST
(1) Disconnect hydraulic hose 511 from
suspension release tee fitting LH
input port.
(2) Connect STE/ICE-R between hydraulic
hose 511 and suspension release
tee fitting LH input port.
(3) Start engine (TM 9-2320-366-10-1).
(4) Position SUSPENSION knob to LOWER
(TM 9-2320-366-10-1).
(5) Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-366-10-1).
(6) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(7) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, go to step 5 of this fault.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace hydraulic hose 511
(para 19-12).
(9) Disconnect STE/ICE-R from hydraulic hose
511 and suspension release tee fitting
LH input port.
(10) Connect hydraulic hose 511 to suspension
release tee fitting LH input port.
(11) Repeat steps (2) through (12) on hydraulic
hose 509 and suspension release tee
fitting RH input port.