PRESSURE TEST
(1) Position drain pan under air/hydraulic
manifold.
(2) Disconnect hydraulic hose 521 from
port P2.
(3) Connect STE/ICE-R between hydraulic
hose 521 and port P2.
(4) Position SUSPENSION knob to LOWER
(TM 9-2320-366-10-1).
(5) Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-366-10-1).
(6) Operate back-up hydraulic pump
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(7) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, go to step 14 of this fault.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace air/hydraulic manifold
(para 19-4).
(9) Disconnect STE/ICE-R from hydraulic hose
521 and port P2.
(10) Connect hydraulic hose 521 to port P2.
Change 1
2-2228.15