TM 9-2320-366-20-3
PRESSURE TEST
(1) Position drain pan under back-up hydraulic
pump.
(2) Disconnect hydraulic hose 520 from
back-up hydraulic pump return port.
(3) Connect STE/ICE-R between hydraulic
hose 520 and return port.
(4) Start engine (TM 9-2320-366-10-1).
(5) Position SUSPENSION knob to LOWER
(TM 9-2320-366-10-1).
(6) Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-366-10-1).
(7) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, go to step 15 of this fault.
(9) Disconnect STE/ICE-R from hydraulic hose
520 and return port.
(10) Connect hydraulic hose 520 to return port.
Change 1