Click here to make tpub.com your Home Page

Page Title: PRESSURE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-3
PRESSURE TEST
(1) Position drain pan under air/hydraulic
manifold.
(2) Disconnect hydraulic hose 514 from
port T1.
(3) Connect STE/ICE-R between hydraulic
hose 514 and port T1.
(4) Start engine (TM 9-2320-366-10-1).
(5) Position SUSPENSION knob to LOWER
(TM 9-2320-366-10-1).
(6) Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-366-10-1).
(7) Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, replace air/hydraulic manifold
(para 19-4).
(9) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace hydraulic hose 514
(para 19-12).
(10) Disconnect STE/ICE-R from hydraulic hose
514 and port T1.
(11) Connect hydraulic hose 514 to port T1.
Change 1
2-2228.11

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business