SOAPY WATER LEAK TEST
(1)
Remove two screws and washers from front
grille.
(2)
Remove screw and washer from front grille.
(3)
Remove front grille from cab.
(4)
Apply soapy water solution to cab floor supply
hose fittings.
(5)
Select RUN FLAT at CTIS ECU
(TM 9-2320-366-10-1).
(6)
Check for bubbles indicating leaks.
(7)
Position front grille on cab with washer and
screw.
(8)
Position two washers and screws in front grille.
(9)
Tighten screw to 48-60 lb-in. (5-7 Nm).
(10)
Tighten two screws to 24 lb-in. (3 Nm).