TM 9-2320-366-20-3
TM
m1. TWO STEADY MODE LIGHTS ILLUMINATE ON CENTRAL TIRE INFLATION SYSTEM (CTIS) ECU (CONT)
m1.
KNOWN INFO
TEST OPTIONS
14.
Air hoses from wet tank
Soapy Water Leak Test
to manifold valve
Are cab floor supply hose
REASON FOR QUESTION
assembly OK.
CTIS may be unable to
fittings free from
Air compressor and
reach selected pressure
leaks and damage?
and two lights will flash if
Wheel valves venting OK.
air leaks from CTIS air
Manifold valve assembly
hoses during inflation/
relief valve OK.
deflation.
Manifold valve assembly
OK.
Quick release valves OK.
Rear axle quick
release valve fittings OK.
Intermediate axle quick
NO
release valve fittings OK.
Intermediate axle tee
fittings OK.
Front quick release valve
Tighten loose air hoses.
fittings OK.
Replace damaged air hoses
Front tee fittings OK.
and/or fittings (para 23-2).
Manifold valve assembly
delivery port fittings OK.
POSSIBLE PROBLEMS
Faulty cab floor supply
hose fittings.
YES
Faulty supply hoses from
quick release valve(s) to
wheel valve(s).
Faulty wheel valve filters.
Faulty electrical connections
at CTIS ECU and manifold
valve assembly.
Faulty ECU.
2-2034
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |