(1) Disconnect (air compressor to purge valve)
air hose form air compressor and purge valve.
(2) Blow through one end of air hose. If no
air escapes from other end of air hose,
air hose is blocked.
(3) Connect (air compressor to purge valve) air
hose to air compressor.
(4) Lower cab (TM 9-2320-366-10-1).
(1) Start engine (TM 9-2320-366-10-1).
(2) Check for presence of air at (air compressor
to purge valve) air hose.
(3) If no air escapes from air hose, Adjust or
replace air compressor governor (para 11-31).
(4) If air escapes from air hose, service air dryer
for faulty purge valve (para 23-11).
(5) Shut down engine (TM 9-2320-366-10-1).
(6) Connect (air compressor to purge valve)
air hose to air dryer purge valve.