TM 9-2320-366-20-2
j1. AIR SYSTEM LOSES PRESSURE DURING OPERATION/SLOW, NO, OR INCORRECT AIR
PRESSURE BUILDUP (CONT)
KNOWN INFO
TEST OPTIONS
6.
Soapy Water Leak Test and
FRONT BRAKE/REAR BRAKE
Visual Inspection
AIR pressure gages OK.
Are air hoses from wet tank
REASON FOR QUESTION
Air hoses and fittings from air
to primary and secondary
cleaner to air compressor OK.
A leaking or damaged air
air tanks, check valves, and
Air hoses and fittings from air
hose or fitting may cause air
fittings free from damage?
compressor to air dryer OK.
system to loose pressure or
Air hose and fittings from
take an excessive amount of
air dryer to wet tank OK.
time to build up air pressure.
Air hoses and fittings from
wet tank to air compressor OK.
POSSIBLE PROBLEMS
Damaged air hoses from wet
tank to primary and secondary
air tanks.
NO
Faulty check valves at primary
and secondary air tanks.
Faulty air dryer purge valve
and/or clogged desiccant
cartridge.
Faulty air compressor
governor.
Replace damaged air hose
YES
Faulty air compressor.
and/or fittings (para 23-2).