TM 9-2320-366-20-2
j1. AIR SYSTEM LOSES PRESSURE DURING OPERATION/SLOW, NO, OR INCORRECT AIR
PRESSURE BUILDUP (CONT)
KNOWN INFO
TEST OPTIONS
4.
Soapy Water Leak Test and
FRONT BRAKE/REAR BRAKE
Visual Inspection
AIR pressure gages OK.
Are air hose from air dryer
REASON FOR QUESTION
Air hoses and fittings from air
to wet tank and fittings
cleaner to air compressor OK.
A leaking or damaged hose
free from leaks or damage?
Air hoses and fittings from air
or fitting may cause air system
compressor to air dryer OK.
to loose pressure or take
POSSIBLE PROBLEMS
an excessive amount of
time to build up air pressure.
Damaged air hose from air
dryer to wet tank.
Damaged air hose from wet
tank to air compressor.
Damaged air hoses from wet
NO
tank to primary and secondary
air tanks.
Faulty check valves at primary
and secondary air tanks.
Faulty air dryer purge valve
and/or clogged desiccant
cartridge.
Replace damaged air hose
YES
Faulty air compressor
and/or fittings (para 23-2).
governor.
Faulty air compressor.
2-1954
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |